Aanbevolen stroombereik en toepassingen
|
Vermogensbereik |
Typische toepassingen |
|
25–90kva |
Residentiële back -up, landelijke telecomlocaties, kleine winkels |
|
100–250kva |
Ziekenhuizen, hotels, kantoorgebouwen, boerderijen |
|
300–600KVA |
Productie -fabrieken, logistieke centra, industriële workshops |
|
800–1200KVA |
Datacenters, luchthavens, grote - schaal commerciële complexen |
|
1500–4125kva |
Power stations, mijnbouwactiviteiten, olie- en gasfaciliteiten, back -up van nutsnetwerk |
Beschikbaar in open type, stille luifel, trailer - gemonteerd en containereconfiguraties.
Technische specificaties (voorbeeldmodellen)
|
Model nr. |
Standby -kracht |
Prime power |
Motormodel |
Spanning |
Frequentie |
Configuratie |
|
W30 |
30KVA |
27kva |
WP2.3D33E200 |
230/400V |
50Hz |
Stil / open |
|
W150 |
150KVA |
135kva |
WP6D152E200 |
230/400V |
50Hz |
Stil / trailer |
|
W500 |
500kva |
450kva |
12M26D660E200 |
230/400V |
50Hz |
Bedekt |
|
W1000 |
1000KVA |
900kva |
12M33D1100E200 |
400/690V |
50Hz |
Bedekt |
|
W2000 |
2000kva |
1800kva |
16M33D2100E200 |
400/690V |
50Hz |
Bedekt |
|
W3300 |
3300 kW |
3000 kW |
16M55D3300E200 |
400/690V |
50Hz |
Bedekt |
|
W4125 |
4125kva |
3750kva |
16M55D4125E200 |
400/690V |
50Hz |
Bedekt |
Aangepast 60H
Belangrijkste kenmerken van Weichai dieselgenerators
- Echte Weichai -motoren- Bewezen stabiliteit, hoge efficiëntie en lange operationele levensduur.
- Ultra - breed vermogensbereik- van 25kva tot 4125kva, die klein is voor mega - schaalvermogen eisen.
- Duurzame en flexibele configuraties- Opentype, stille luifel, trailer en containerized eenheden.
- Slimme besturingsopties- geïntegreerde Deepsea, Comap of SmartGen -controllers.
- Exporteren - Gereed compliance- CE / ISO gecertificeerd, ontworpen voor wereldwijde marktstandaarden.

Oproep tot actie
Neem vandaag nog contact met ons op voor Weichai Generator Set prijzen, specificaties of aanpassingsgegevens.


Populaire tags: Weichai Generator Set, China Weichai Generator Set Leveranciers, Factory
Parameterlijst van de weichai -generatorset parametertabel
| Eenheidsmodel | Uitgangsvermogen (KW) | Elektrische stroom (a) | Type dieselmotor | Aantal cilinders | Boordiameter * slag (mm) | Uitlaatvolume (l) | Smeer oliecapaciteit (L) | Brandstofverbruiksnelheid/kw.h | Eenheidsgrootte (mm) L × W × H | Eenheid gewicht kg | |
| Kw | KVA | ||||||||||
| Weichai Power Yangchai -serie | |||||||||||
| 16GF | 16 | 20 | 28.8 | WP2.1D18E2 | 4 | 85*92 | 2.09 | 12 | 235 | 1500*630*1100 | 650 |
| 20GF | 20 | 25 | 36 | WP2.5D22E2 | 4 | 90*100 | 2.54 | 12 | 235 | 1550*630*1150 | 660 |
| 30GF | 30 | 37.5 | 54 | WP3.9D33E2 | 4 | 102*118 | 3.86 | 12 | 235 | 1600*650*1180 | 800 |
| 34GF | 34 | 42.5 | 61.2 | WP4.3D38E2 | 4 | 105*125 | 4.33 | 12 | 235 | 1600*650*1180 | 800 |
| 40GF | 40 | 50 | 72 | WP4.6D44E2 | 4 | 108*125 | 4.58 | 12 | 235 | 1600*650*1180 | 820 |
| 48GF | 48 | 60 | 86.4 | WP4.1D50E2 | 4 | 105*118 | 4.09 | 12 | 215 | 1700*600*1100 | 900 |
| 58GF | 58 | 72.5 | 104.4 | WP4.3D61E2 | 4 | 108*118 | 4.32 | 12 | 210 | 1800*650*1200 | 950 |
| Weichai Power Deutsch | |||||||||||
| 50GF | 50 | 62.5 | 90 | WP4D66E200 | 4 | 105*130 | 4.5 | 28 | 198 | 1950*950*1340 | 1100 |
| 60 GF | 60 | 75 | 108 | WP4D66E200 | 4 | 105*130 | 4.5 | 28 | 198 | ||
| 80 GF | 80 | 100 | 144 | WP4D100E200 | 4 | 105*130 | 4.5 | 28 | 198 | 2200*920*1340 | 1250 |
| 90 gf | 90 | 112.5 | 162 | WP4D100E200 | 4 | 105*130 | 4.5 | 28 | 198 | ||
| 90 gf | 90 | 112.5 | 162 | WP4D108E200 | 4 | 105*130 | 4.5 | 28 | 198 | 2200*920*1340 | 1250 |
| 100 gf | 100 | 125 | 180 | WP4D108E200 | 4 | 105*130 | 4.5 | 28 | 198 | ||
| 100 gf | 100 | 125 | 180 | WP6D132E200 | 6 | 105*130 | 6.75 | 35 | 198 | 2470*930*1450 | 1550 |
| 120GF | 120 | 150 | 216 | WP6D132E200 | 6 | 105*130 | 6.75 | 35 | 198 | ||
| 120GF | 120 | 150 | 216 | WP6D152E200 | 6 | 105*130 | 6.75 | 35 | 198 | 2470*930*1450 | 1620 |
| 132GF | 132 | 165 | 237.6 | WP6D152E200 | 6 | 105*130 | 6.75 | 39 | 198 | ||
| Weichai Power Blue | |||||||||||
| 180 gf | 150 | 187.5 | 270 | WP10D200E200 | 6 | 126*130 | 9.726 | 35 | 195 | 2600*950*1400 | 1650 |
| 200 GF | 200 | 250 | 360 | WP10D238E200 | 6 | 126*130 | 9.726 | 35 | 195 | 2750*970*1800 | 2100 |
| 240GF | 220 | 275 | 396 | WP10D264E200 | 6 | 126*130 | 9.726 | 35 | 195 | 2800*970*1800 | 2200 |
| 280GF | 250 | 312.5 | 450 | WP12D317E200 | 6 | 126*155 | 11.596 | 38 | 195 | 2850*970*1800 | 2300 |
| 300GF | 300 | 375 | 540 | WP13D385E200 | 6 | 127*165 | 12.54 | 48 | 195 | 2900*970*1800 | 2400 |
| 350GF | 300 | 375 | 540 | WP13D385E200 | 6 | 127*165 | 12.54 | 48 | 195 | 2950*970*1800 | 2500 |
| 400GF | 400 | 500 | 1010 | WHM6160D518 | 6 | 160*200 | 15.9 | 65 | 195 | 3850*1340*1955 | 5700 |
| Weichai Power | |||||||||||
| 440GF | 440 | 550 | 792 | 6M26D484E200 | 6 | 150*150 | 15.9 | 65 | 195 | 3500*1500*2000 | 4800 |
| 880GF | 880 | 1100 | 1584 | 12M26D968E200 | 12 | 150*150 | 31.8 | 120 | 195 | 4500*1700*2450 | 8500 |
| 1000 gf | 1000 | 1250 | 1800 | 12M33D1210E200 | 12 | 150*185 | 39.2 | 146 | 210 | 4800*1800*2450 | 9500 |


























